Programming the Yale Real Living Touchscreen Deadbolt 220/240

Programming the Yale Real Living Touchscreen Deadbolt 220/240

yaletouchprogramming1

A unique Master PIN Code must be entered prior to any further programming of the lock. 

yaletouchprogramming2

Definitions

All Code Lockout Mode: This feature is enabled by the Master PIN code. When enabled, it restricts all user PIN code access (except the Master PIN code). When the unit is in Lockout Mode, the red locked padlock (see above) will appear on the screen when attempting to enter a PIN code.

Automatic Re-lock Time: After successful code entry and the unit unlocks, it will automatically re-lock after a default of thirty (30) seconds. Re-lock time is adjustable* from 10-180 seconds.

Inside Indicator Light: Located on the inside escutcheon, it shows active status (Locked) of lock and can be enabled or disabled in the Advanced Lock Settings (Main Menu selection #3).

Language Setting Mode: Choosing English (1), Spanish (2) or French (3) becomes the (default) setting for the lock’s voice prompts.

Low Battery: When battery power is low, the Low Battery Warning Indicator flashes RED. If battery power is completely lost, use the cylinder key override.

Master PIN Code: The Master code is used for programming and for feature settings and must be registered prior to programming the lock. The Master code will also operate the lock.

Network Module Setting: With the optional Network Module installed, this setting becomes available through the Main Menu (7) and allows the lock to connect with a network controller.

One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-lock the lock.

Previous: While in Menu Mode, pressing this icon (#3 above) cancels the current operation and returns the user to the previous step.

Privacy Mode Button: Pressing and holding the Privacy button (found below thumbturn) for a duration of four beeps deactivates the keypad, and because it is set from the inside, provides a secure lock for the convenience of the occupant(s).

Shutdown Time: The unit will shutdown (flashing RED) for a default* of sixty (60) seconds (time is adjustable* from 10-180 seconds) and not allow operation after the wrong code entry limit (see below) has been met.

Tamper Alert: Audible alarm if attempting to forcibly remove outside lock from door.

User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. When deleting User PIN code(s), screen will display User Number (not PIN code) being deleted.

Volume Setting Mode: The volume setting for PIN code verification is set to Low (2) by default; otherwise it can be set to Silent (3) for quiet areas, or it can be set to High (1). 

Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a PIN code the unit will shut down and not allow operation. Default is (5). Limit is adjustable* from one (1) to ten (10) times.

Feature Programming Through Menu Mode Using Master PIN code

Enter the 4-8 digit Master PIN code followed by the “#” key.

2. Enter digit corresponding to the function to be performed followed by the “#”  key.

Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit. 

yaleprogramming3

Screen Shot 2015-01-30 at 3.31.37 PM