This article applies to the following models: Centralite 3 Series Lamp Module Centralite 3 Series Appliance Module Centralite Azela Lamp Module Centralite Azela Appliance Module Verify that the wall outlet is powered. If the wall outlet is powered by a wall switch, then the wall switch MUST be kept ON…
Defaulting the PEARL Thermostat
To default the thermostat, place the thermostat into programming mode by pressing between the hold button and the fan button. While continuing to hold between the hold button and the fan button, swipe down on the right slider until “01″ is displayed. When the “01” is displayed, it indicates you are in “programming mode.”…
Defaulting SMC Water Sensor
To default the sensor, remove the battery. While pressingthe black Tamper/Default button located near the battery carrier and the wire contacts, insert the battery. Then release the button.
Defaulting Centralite AZELA In Wall Light Switch
1. Lift the air-gap switch at the bottom of the rocker to OFF position to power down the device. 2. Hold down the UP button 3. Push In the air-gap switch to ON position to power up the device. 4. Release UP button within 4 seconds after…
Defaulting the Visonic Carbon Monoxide Alarm (MCT-442 SMA)
Hold down the tamper switch on the bottom of the device. Insert the battery into the sensor. Wait for the RF module’s green LED to light. In order to see the green LED on the circuit board, the cover must be separated from the housing (to expose the circuit board)…
Defaulting a Centralite AZELA Thermostat
To default the thermostat, first remove the thermostat cover and batteries. Place two batteries into the thermostat(the positive terminals will face left) Press and hold the reset button(top left) and the hold button(bottom center). Release the reset button while keeping the hold button depressed. When the screen begins to come…
Defaulting the CLIP Motion Detector
To default the CLIP Motion Sensor, remove the cover by loosening the screw at the bottom of the unit to expose the circuit board and battery. Remove the battery and press and hold the tamper spring. With the tamper spring held down, insert the battery, immediately release the tamper spring,…
Defaulting the Visonic Pet-immune Motion Detector (NEXT-K85-SMA)
Open the cover by loosening the small screw at the bottom of the sensor and expose the circuit board and remove the circuit board. Locate the battery on the back side of the board and remove it. With the battery removed, press and hold the tamper spring. Reinsert the battery…
Defaulting the Visonic Water Sensor (MCT-550 SMA)
To default the Water Sensor, remove the cover by loosening the screw found at the top of the unit. Remove the battery and depress the tamper spring. Reinsert the battery, immediately release the tamper spring, and press and release the tamper spring again. The LED on the sensor will begin…