Open the cover by loosening the small screw at the bottom of the sensor and expose the circuit board and remove the circuit board. Locate the battery on the back side of the board and remove it. With the battery removed, press and hold the tamper spring. Reinsert the battery…
Defaulting the Visonic Water Sensor (MCT-550 SMA)
To default the Water Sensor, remove the cover by loosening the screw found at the top of the unit. Remove the battery and depress the tamper spring. Reinsert the battery, immediately release the tamper spring, and press and release the tamper spring again. The LED on the sensor will begin…
Defaulting the Visonic MINI Door/Window Sensor (MCT-320-SMA)
To default the slimline door/window sensor: 1) Remove the cover using a small flathead screwdriver. 2) Remove the battery; press and hold down the tamper switch(small black button near battery). 3) With the tamper switch still held down, insert the battery and release the tamper switch. 4) The LED…
Defaulting the SMC Door Window Sensor Rev 2 (SMCDW02-Z)
Door/Window sensors are used for monitoring entry and exit areas of your home, as well as perimeter areas. The door/window sensor can be placed on any door or window. Be sure to place the smaller magnet on the part of the surface that will have the most amount of motion(i.e.…
Managing Your Hub – Hard Reboot
Sometimes it is necessary to reboot networking equipment and the hub is no exception. When you experience network related problems, follow these simple steps. 1) Power off the HUB for 30 seconds and restore power. 2) Wait for the second light from the bottom to flash AMBER. 3) Are you…
Verifying Broadband Connectivity
The Ethernet cable coming from your internet connection should be in the WAN port and the LEDs should look like this. The power LED should be GREEN The Network LED should be blinking AMBER If your LEDs are properly lit, connect a PC to the LAN port…